Checks a single axially loaded, braced column against the capacity your standard's values produce, with every step of the arithmetic shown: slenderness from your effective length factor, capacity from

SKILL.md

GitHub

Design Column

Take a load, a length, and a trial section, and show the arithmetic that says whether the column carries it. The slenderness arithmetic is the same everywhere. The buckling curve, the factors, and the properties are not, so they come from you.

Scope and limits — read first

What this does. Combines your loads under your combinations, computes slenderness from the effective length factor you supply, evaluates the capacity expression you supply with your material and section values in it, and reports demand over capacity with every step visible.

What this does not do.

  • It does not know any engineering values. No effective length factors, no buckling curves or column formulas, no material strengths, no section properties, no resistance or safety factors. Every one comes from you, cited. That is the design, not a gap.
  • It does not pick K. The effective length factor is a judgment about restraint, and it changes the answer more than most inputs; you supply it and it is printed beside the result.
  • One member, one storey segment, braced against sway, concentric axial load. Sway frames, stepped or tapered members, and built-up sections stop the run.
  • Combined axial and bending runs only if you supply the interaction equation from your standard, written out. Otherwise it stops rather than checking the axial term alone and calling it done.
  • It does not size base plates, connections, or splices, and it does not check fire resistance.
  • It does not generate loads and does not chase load paths down a building; the load at the top of this column is yours.

What you need before starting. The design standard and edition, the method, the unbraced lengths about each axis, your K, the loads and combinations, and the section, material, and capacity values from your own tables.

Workflow

Step 1. Establish the standard and the method

Ask, in one message:

  1. Which design standard governs, and which edition?
  2. Which design method: limit states with factored loads, allowable stress, partial factors, or another?
  3. Material: steel, sawn timber, glulam, or reinforced concrete.
  4. How will you supply values? Type them, paste the table, or name a file.

If the answer to 2 is unclear, stop; a capacity from one method against loads from another is wrong by the size of the factors.

Step 2. Collect geometry and loads

Unbraced length about each axis, and the K you assign to each, with a word on the restraint that justifies it. Loads by source, unfactored. Bracing that differs by axis is normal; bracing that is unclear stops the run.

Anything unstated is missing. Never substitute a typical value, and never assume a load is zero because it was not mentioned.

Step 3. Collect the values

Accept a typed value with its citation, a pasted table, or a file. If none arrives, the run stops at that value and says so.

Value Needed for
Load combinations, written out Factoring the loads
Section area and radii of gyration, both axes Slenderness and capacity
Material strength and modulus Capacity
The capacity expression or tabulated capacity, cited Capacity
Resistance, safety, or adjustment factors, each named Capacity
Slenderness limit, if your standard sets one The slenderness check

A tabulated capacity is welcome: paste the row, name the table, and the check uses it directly, printed with its citation.

Step 4. Compute, showing every step

Loads
  <each load, as given, with units and source>
Combination used            <written out, cited>
  factored axial load       <arithmetic>
Slenderness
  KL/r, each axis           <arithmetic>
  governing axis            <which and why>
  limit (if supplied)       <as given, cited> — <pass/fail>
Capacity
  <each input, cited>
  expression, as supplied   <written out>
  capacity                  <arithmetic>
Ratio
  demand / capacity         <value>

Every input line carries where it came from. If any input is unverified, the result for that line reads unverified, not a number.

Step 5. If no trial section was given

Do not name one. Report what the demand implies instead: the capacity the section must deliver at your factors, and, where the expression allows it, the section property that capacity implies. Then say plainly to pick a section from your own tables and come back with it.

Step 6. Report

The ratio, the governing axis, the slenderness result, and the list of anything unverified. Then:

Every factor, property, and expression here came from you. I did the arithmetic and supplied no engineering values. This is a preliminary check of a braced, concentrically loaded member, and it is not a design. The Engineer of Record designs the column.

Step 7. Save, if asked

Ask whether to write the calculation to a file and where. Write it directly, including the arithmetic. There is no template and no script.

Rules

  • Never supply an engineering value, and never evaluate a buckling formula you were not handed. There are none in this file.
  • Never pick K. Print the user's K and their reasoning beside the result.
  • Never check the axial term alone when bending exists. Interaction equation or stop.
  • Confirm the design method before collecting values, and never mix methods.
  • Show the arithmetic. Stop on a missing value rather than proceeding with a placeholder.
  • Never convert units, and never round an input to a neater figure.
  • Say on every run that this is preliminary and not a design.

Anti-patterns

  • Supplying K = 1.0 as a harmless default. It is a restraint judgment, not a default.
  • Recalling a column formula because the standard is familiar. Editions move; the formula comes from the user's edition or not at all.
  • Naming a trial section because the load and length make it obvious.
  • Running the check about one axis because the other "clearly" does not govern.
  • Reporting a ratio when one of its inputs was unverified.

Resources