glm-calibration

Calibration strategy for GLM lake temperature simulations, including parameter sensitivity and typical ranges.

SKILL.md

GitHub

GLM Calibration for Lake Temperature

Key Calibration Parameters (Lake Mendota)

Parameter Range Effect
Kw [0.1, 0.5] Light extinction; higher = less deep heating, stronger stratification
coef_mix_hyp [0.3, 0.7] Hypolimnetic mixing; higher = more deep mixing, warmer hypolimnion
wind_factor [0.7, 1.3] Wind speed multiplier; higher = more surface mixing
lw_factor [0.7, 1.3] Longwave radiation multiplier; affects surface energy balance
ch [0.0005, 0.002] Sensible heat transfer coefficient

Calibration Strategy

  1. Start with defaults, run, compute RMSE
  2. Adjust Kw first (strongest control on stratification)
  3. Then coef_mix_hyp (controls deep temperatures)
  4. Fine-tune wind_factor and lw_factor for surface/overall bias
  5. ch has moderate effect on surface heat exchange

RMSE Computation

  • Match observations to simulation by exact datetime and rounded depth
  • depth_sim = round(lake_depth - z) to get depth from surface
  • Overall RMSE, deep (>=13m) RMSE, summer deep (Jun-Sep, >=13m) RMSE