fsi-analysis
Use when analyze fluid-structure interaction effects in a spacecraft or launch vehicle structural assembly per ECSS-E-ST-32 clause 4.6.2.7: identify sloshing loads from propellant or fluid-filled tank
SKILL.mdskills/space-systems/ecss/fsi-analysis/SKILL.md
GitHubECSS Structures — Fluid-Structure Interaction Analysis (space-systems/ecss/fsi-analysis)
Use when the task is to analyze fluid-structure interaction effects in a spacecraft or launch vehicle per ECSS-E-ST-32 clause 4.6.2.7 — covering propellant sloshing in tanks, hydroelastic coupling between structural modes and enclosed fluid volumes, and aerodynamic buffet excitation during atmospheric flight.
Domain quick reference
- Clause 4.6.2.7 identifies three FSI effect families that must be assessed for any structure containing fluid or exposed to unsteady aerodynamic loading: sloshing (propellant or fluid motion inside a tank that exerts dynamic loads on the tank walls and shifts the vehicle's center of mass), hydroelastic coupling (interaction between a structural vibration mode and the inertia of the enclosed fluid, which lowers the effective natural frequency), and buffet (turbulent boundary-layer pressure fluctuations on the external skin during launch or atmospheric transit that produce broadband dynamic loads).
- Sloshing is characterized by its fundamental lateral frequency, which depends on tank radius, fill level, and effective gravity. The sloshing fluid can be modeled as an equivalent pendulum whose length is derived from that frequency. Low fill fractions (below ~30%) and high fill fractions (above ~85%) both require special attention: partial fill maximizes the participating sloshing mass at intermediate levels.
- Hydroelastic coupling is significant when the effective sloshing mass (approximately 63% of the total fluid mass for a cylindrical tank in the fundamental mode) exceeds roughly 5% of the structural dry mass. When coupling is significant, the coupled natural frequency is lower than the dry structural frequency by a factor of 1/sqrt(1 + added-mass ratio), and the reduced frequency must still satisfy the launcher or mission interface frequency requirement.
- Buffet loads are estimated from the freestream dynamic pressure, an exposed reference area, and an empirical buffet pressure coefficient. The resulting RMS force must be compared against the structural allowable for the affected panel or component. Buffet is most severe near maximum dynamic pressure (max-q) during ascent.
Workflow
- Inventory every tank, fluid-wetted volume, and external surface exposed to unsteady aerodynamic loading. For each tank, record tank inner radius, fill fraction, fluid density, and structural dry mass. For each external surface, record the reference area and the dynamic pressure at the critical flight condition (max-q).
- For each tank, compute the fundamental lateral sloshing frequency using the cylindrical tank formula (Bessel root chi_11 = 1.8412, effective fluid height, and tank radius). Derive the equivalent pendulum length from that frequency and confirm it is consistent with the geometric fill level.
- Compute the effective added sloshing mass using the 63% sloshing-mass fraction for the fundamental mode of a cylindrical tank. Compute the added-mass ratio (sloshing mass / structural dry mass). Determine whether hydroelastic coupling is significant (ratio > 0.05) or negligible.
- Where coupling is significant, compute the coupled natural frequency: f_coupled = f_dry / sqrt(1 + added-mass ratio). Compute the fractional frequency shift. Check that f_coupled satisfies the minimum frequency requirement from the launcher interface control document or mission requirements; flag any case that fails.
- For each external surface at the critical flight condition, compute the RMS buffet load: dynamic pressure x reference area x buffet pressure coefficient. Compare against the structural allowable for that surface; flag any case that exceeds the allowable.
- Aggregate findings: a structural case is FSI-compliant only when its coupled frequency margin passes and its buffet load margin passes. Report non-compliant cases and identify the dominant FSI effect driving the finding.
Pitfalls
- Applying the dry structural frequency to meet frequency requirements without accounting for the coupled (fluid-loaded) frequency — hydroelastic coupling can lower the frequency by 10–30% for propellant-heavy configurations, which may violate launcher interface requirements that appeared to be met.
- Using total fluid mass instead of the participating sloshing mass in the added-mass ratio — the entire propellant load does not slosh; only the fraction near the free surface participates, and overestimating this leads to unnecessarily conservative frequency corrections.
- Ignoring sloshing at high fill fractions under the assumption that "the tank is nearly full so there is no sloshing" — the sloshing frequency increases at high fill, but the loads on the tank dome can still be significant and must be checked.
- Treating buffet as a static load rather than a broadband dynamic excitation — the RMS load is the starting point; if the buffet spectral content overlaps a structural mode, dynamic amplification must be included and the peak load can substantially exceed the RMS value.
Behavior contract (gate 3)
The sloshing frequency, added-mass ratio, hydroelastic coupling determination, buffet load computation, frequency-shift correction, and margin checks are exercised by the gate 3 contract test: scripts/test_fsi_analysis.py against scripts/fsi_analysis_logic.py (stdlib unittest, offline). Run: python3 scripts/test_fsi_analysis.py
Compliance
- ECSS standards are freely downloadable (ESA); cite the source and paraphrase per standards-map.yaml.
- compliance: STANDARDS-REF, gated: false.