e1012-set

Use when compute Single Event Transient (SET) rates for a spacecraft device population under ECSS-E-ST-10C §9.4.1.7: identify each sensitive device and its cross-section model (Weibull for heavy ions,

SKILL.md

GitHub

ECSS Space Environment — Single Event Transients (space-systems/ecss/e1012-set)

Use when the task is computing Single Event Transient (SET) rates for spacecraft electronics under ECSS-E-ST-10C §9.4.1.7 — integrating device cross-section models against the mission heavy-ion, proton, and neutron environments and checking each device's total SET rate against its system-level budget.

Domain quick reference

  • An SET is a radiation-induced transient voltage or current pulse in a circuit, caused by the passage of a single ionizing particle (heavy ion, proton) or a nuclear reaction product from neutron/proton spallation. Unlike a Single Event Upset (SEU), an SET does not alter a storage element — it propagates as a glitch through combinational logic or an analog circuit until it is captured or dissipates. Sensitive device types include analog ICs, clock buffers, ADCs, comparators, and fast logic.
  • Heavy-ion SET rates are computed by integrating the device's cross-section versus LET curve over the mission differential LET spectrum. The cross-section is typically fit with a four-parameter Weibull function: LET threshold L_th (MeV·cm²/mg), saturation cross-section σ_sat (cm²/device), width W (MeV·cm²/mg), and shape exponent s (dimensionless). Below L_th the cross-section is zero; above L_th it rises to σ_sat following the Weibull shape.
  • Proton SETs arise when energetic protons or their nuclear reaction products deposit sufficient charge. The cross-section is modeled as a threshold/step function: zero below an energy threshold E_th (MeV) and equal to σ_sat above it. A more detailed Weibull proton model may be substituted when device characterization data warrant it.
  • Neutrons do not ionize directly; they produce SET-causing charge via elastic nuclear recoils and spallation fragments. The rate is approximated as the total neutron flux (particles/cm²/s) multiplied by an effective cross-section (cm²/device).
  • The total SET rate is the sum of heavy-ion, proton, and neutron contributions, expressed in events/device/day. Each sensitive device must have a system-derived allowable SET rate budget; any exceedance is a compliance finding. A device with no budget on record is also a finding — an absent budget means the system requirement was never captured, not that no limit applies.

Workflow

  1. Inventory every sensitive device in scope (analog ICs, logic gates, clock buffers, ADCs, comparators). For each device, record its cross-section model parameters: Weibull (L_th, σ_sat, W, s) for heavy ions; threshold energy E_th and σ_sat for protons; effective cross-section σ_n for neutrons. Reject a device record that is missing any required parameter before it enters the rate calculation.
  2. Obtain the mission particle environment for the target orbit: the differential heavy-ion LET spectrum in particles/(cm²·s·MeV·cm²/mg), the differential proton energy spectrum in particles/(cm²·s·MeV), and the total neutron flux in particles/(cm²·s). Verify all flux values are non-negative; a negative flux is a data error, not a conservative choice.
  3. Compute the heavy-ion SET rate for each device: evaluate the Weibull cross-section σ(LET) at each spectral LET point, then integrate σ(LET) × φ(LET) over the full LET range using the trapezoidal rule. Multiply by 86 400 s/day to convert to events/device/day.
  4. Compute the proton SET rate for each device: apply the threshold cross-section model (σ = σ_sat for E ≥ E_th, else 0), integrate σ(E) × φ(E) over the proton energy spectrum with the trapezoidal rule, and convert to events/device/day.
  5. Compute the neutron SET rate for each device as: R_n = σ_n × Φ_n × 86 400 (events/device/day), where Φ_n is the total neutron flux in particles/(cm²·s).
  6. Sum the three contributions to the total SET rate per device. Compare each total against the device's allowable SET rate budget. Flag every exceedance as a compliance finding. Separately flag every device for which no budget is on record as a requirement-capture gap.

Pitfalls

  • Substituting the saturation cross-section σ_sat for the full Weibull curve and integrating the entire spectrum at that constant value — the Weibull roll-on suppresses σ sharply near L_th and the step-function approximation overpredicts risk for spectra that are LET-soft (heavy on low-LET particles).
  • Omitting the neutron contribution for orbits with significant trapped or secondary neutron flux (e.g. low-altitude equatorial) — the neutron rate can be comparable to the proton rate for devices with low effective cross-section thresholds.
  • Reading a missing budget as zero exceedance — an absent budget means the system requirement was never captured, which is itself a compliance finding, not a pass.
  • Summing contributions that were integrated over different mission durations without normalizing — reduce all three to a common per-day basis before adding them.
  • Applying the proton model to energies below the device's nuclear reaction threshold without zeroing the cross-section — direct ionization by protons is negligible below ~10–30 MeV for most devices and the threshold model must drop to zero in that regime.

Behavior contract (gate 3)

The Weibull cross-section evaluation, heavy-ion trapezoidal integration, proton threshold integration, neutron rate formula, total rate summation, and budget compliance check logic is exercised by the gate 3 contract test: scripts/test_e1012_set.py against scripts/e1012_set_logic.py (stdlib unittest, offline). Run: python3 scripts/test_e1012_set.py

Compliance

  • ECSS standards are freely downloadable (ESA); cite the source and paraphrase per standards-map.yaml.
  • compliance: STANDARDS-REF, gated: false.