e1004-b6-esp
Use when generating the Annex B.6 Emission of Solar Protons (ESP) worst-case fluence spectra for a mission under ECSS-E-ST-10-04C: build the reference annual integral fluence spectrum, apply the confi
SKILL.mdskills/space-systems/ecss/e1004-b6-esp/SKILL.md
GitHubECSS Emission of Solar Protons (ESP) Fluence Spectra (space-systems/ecss/e1004-b6-esp)
Use when the task is generating the Annex B.6 Emission of Solar Protons (ESP) worst-case fluence spectra under ECSS-E-ST-10-04C, to obtain a design integral fluence-above-energy spectrum for a solar-proton radiation-design case.
Domain quick reference
- The ESP model is probabilistic, not deterministic: instead of a single fixed event spectrum, it returns a design fluence keyed to two case parameters -- the mission's exposure duration and a design confidence level (the probability that the true mission fluence will not exceed the returned value).
- Longer exposure duration raises the design fluence: a longer mission has more opportunity to encounter a large solar-proton event, so its worst-case fluence grows with duration, though not in direct proportion to it.
- A higher confidence level raises the design fluence: bounding a larger fraction of the event-size probability distribution requires reaching further into the rare, large-event tail, so fluence grows as the confidence level approaches its upper limit.
- The model reports fluence at a fixed set of proton energy thresholds (an integral spectrum: fluence of protons at or above each threshold energy), not a continuous differential spectrum and not a peak (instantaneous) flux -- confusing the ESP integral design fluence with a peak flux figure understates or overstates dose/SEE-rate estimates depending on which quantity the downstream calculation actually needs.
- Most radiation-design guidance treats a confidence level below about 90% as insufficient for a worst-case design fluence; lower confidence levels are appropriate only for trade studies or non-worst-case sensitivity analysis, not for the design case itself.
- This leaf scopes ESP fluence-spectrum generation and the worst-case confidence-level check only. Rolling the ESP result into the mission radiation environment specification alongside GCR (sibling e1004-gcr leaf) and trapped-radiation environments is the sibling e1004-rad-env-spec leaf (clause 9.3).
Workflow
- For each solar-proton radiation-design case, record its mission exposure duration (years), the design confidence level (percent) the case requires, and the energy thresholds the downstream shielding/dose/SEE-rate calculation needs.
- Build the reference 1-year, 50%-confidence annual integral fluence spectrum across the model's supported energy thresholds.
- Compute the confidence-level scale factor for the case's design confidence level; verify the requested level falls within the model's supported range before scaling.
- Compute the mission-duration scale factor for the case's exposure duration.
- Apply both scale factors to the reference spectrum to assemble the case's design fluence-above-energy spectrum at each requested threshold energy.
- Check that the assembled spectrum still decreases monotonically with increasing energy threshold -- the expected shape of an integral fluence spectrum -- flagging any deviation before the result is used downstream.
- Mark the case compliant only when its design confidence level meets the mission's worst-case threshold and its spectrum passes the monotonicity check; roll every case's compliance into the assessment record and do not close the radiation environment specification while any case remains non-compliant.
Pitfalls
- Selecting a design confidence level below the mission's worst-case threshold (e.g. using a trade-study confidence level for the actual design case), understating the design fluence and the resulting shielding, dose, or SEE-rate margin.
- Treating the ESP integral fluence-above-energy spectrum as a continuous differential spectrum or as a peak (instantaneous) flux, which produces the wrong input to a downstream shielding, total-dose, or SEE-rate calculation expecting a different quantity.
- Reusing a design fluence computed for one mission duration on a mission with a different exposure duration instead of recomputing the duration scale factor, understating fluence for a longer mission or over-designing for a shorter one.
- Querying the spectrum at an energy threshold the model does not support instead of at one of its defined thresholds, or silently substituting a nearby threshold's fluence without accounting for the spectrum's shape between thresholds.
Behavior contract (gate 3)
The confidence-level scaling, duration scaling, spectrum assembly, monotonicity check, and worst-case compliance logic is exercised by the gate 3 contract test: scripts/test_e1004_b6_esp.py against scripts/e1004_b6_esp_logic.py (stdlib unittest, offline). Run: python3 scripts/test_e1004_b6_esp.py
Compliance
- ECSS standards are freely downloadable (ESA); cite the source and paraphrase per standards-map.yaml.
- compliance: STANDARDS-REF, gated: false.