e1003-el-emc

Use when running element electromagnetic compatibility tests under ECSS-E-ST-10-03C §6.5.5: determine auto-compatibility by verifying that each internal emitter's frequency has sufficient isolation ma

SKILL.md

GitHub

ECSS AIT — Element Electromagnetic Compatibility Tests (space-systems/ecss/e1003-el-emc)

Use when the task is the electromagnetic compatibility assessment of a space element under ECSS-E-ST-10-03C §6.5.5, covering auto-compatibility verification, passive intermodulation (PIM) evaluation for RF-carrying elements, residual magnetic dipole moment measurement, and selection of stand-alone versus embedded test mode per §6.5.5.2.

Domain quick reference

  • §6.5.5 groups element EMC tests into four categories: auto-compatibility (internal emitter vs. internal receiver), passive intermodulation (two carriers mixing in passive components to produce unwanted products), magnetic field measurement (residual dipole moment), and the general EMC conducted/radiated emission and susceptibility suite.
  • §6.5.5.2 separates tests into two modes. Stand-alone mode applies to every element: the element is powered and exercised in isolation under representative electrical boundary conditions. Embedded mode supplements stand-alone when the element is available assembled into its higher-level unit; conducted and radiated susceptibility are the primary candidates for embedded re-check because the higher-level assembly provides realistic cable harness and grounding that cannot be fully replicated stand-alone.
  • Auto-compatibility: a finding occurs when an internal emitter frequency falls inside an internal receive band and the measured isolation margin is below the required minimum. An emitter whose frequency sits outside all internal receive bands requires no margin check against those bands.
  • PIM: applies only to elements with RF transmission paths through passive components (connectors, cables, waveguides, filters, antennas). For each pair of carrier frequencies, odd-order intermodulation products (3rd, 5th, 7th, ...) are computed as m·f1 − n·f2 (and m·f2 − n·f1) where m + n equals the order. A product that falls within the element's receive band is a finding.
  • Magnetic field: the element's residual magnetic dipole moment is measured in three orthogonal axes and the vector magnitude is compared against the element-level magnetic budget. Exceeding the budget is a finding.

Workflow

  1. Obtain the element's internal frequency plan (all emitter center frequencies and all receive band definitions) and the EMC requirements (isolation margin per emitter–receiver pair, magnetic dipole budget, PIM-free receive band). Reject an assessment that lacks a frequency plan or magnetic budget.
  2. For auto-compatibility, iterate every emitter–receiver pair: if the emitter frequency lies within the receiver's band, check that the measured isolation margin meets or exceeds the required margin; flag any pair where it does not. Emitter frequencies outside all receive bands are out-of-scope for margin checking and are recorded as not applicable.
  3. If the element carries RF paths through passive components, list every pair of simultaneous carrier frequencies. For each pair, compute odd-order PIM products up to at least the 9th order; flag any product that falls within a receive band.
  4. Measure the element's residual magnetic dipole moment (three axes) and compare the vector magnitude against the budget. Record a finding if the budget is exceeded.
  5. Assign the test mode for each test type per §6.5.5.2: stand-alone is mandatory for the full suite; if the element is available in its assembled higher-level unit, schedule conducted and radiated susceptibility re-checks in embedded mode as a supplement.
  6. Aggregate all findings. The element is compliant for EMC when the auto-compatibility list, the PIM list, and the magnetic finding are all clear.

Pitfalls

  • Skipping PIM evaluation because no active mixing occurs — PIM arises from non-linearity in passive junctions (connector interfaces, cable ferrite material, oxidised contacts) and must be assessed for any element with RF transmission paths, regardless of whether it contains an active mixer.
  • Treating the embedded-mode susceptibility re-check as optional when the element is available assembled — §6.5.5.2 makes the embedded supplement mandatory for susceptibility once the higher-level assembly exists; skipping it leaves the realistic harness/grounding environment unverified.
  • Accepting a zero-margin auto-compatibility result as a pass — the required margin is a positive value set in the EMC requirements; a measured margin of exactly 0 dB is only acceptable if the requirement explicitly allows it.
  • Omitting the magnetic measurement for elements that appear non-magnetic — residual ferromagnetic content in structure, connectors, and PCB materials can produce non-trivial dipoles; the check is mandatory for all elements in the §6.5.5 scope, not limited to elements with obvious magnetic components.

Behavior contract (gate 3)

The auto-compatibility, PIM, magnetic-field, and test-mode-selection logic is exercised by the gate 3 contract test: scripts/test_e1003_el_emc.py against scripts/e1003_el_emc_logic.py (stdlib unittest, offline). Run: python3 scripts/test_e1003_el_emc.py

Compliance

  • ECSS standards are freely downloadable (ESA); cite the source and paraphrase per standards-map.yaml.
  • compliance: STANDARDS-REF, gated: false.